HMS‐ HMT‐Inverter and DTU‐WLite‐S DTU‐Pro‐S
OutdoorRob edited this page 2025-08-03 20:31:59 +02:00

HMS- / HMT-Inverter and DTU-WLite-S / DTU-Pro-S Details

Links to Whitepapers, FCC IDs and HMS-101 Module Details

Closeup Photos of the disassembled DTU-WLite-S / DTU-Pro-S and HMS-101 Modules without protective metal sheet

Links to several GitHub issues which have so far documented the details


  1. CMT2300A RX/TX-Module

What is the current process flow (communication between ARM-Chip and CMT2300A)?

After switching on the DTU, the initialization phase starts. This is where configurations in memory are retrieved and sub-areas in the DTU are configured with this information. A CMT2300A chip is installed in the transmitter and receiver unit. This chip takes on various tasks and has its task in receiving data from the inverter and forwarding it to the ARM chip. Just as well to send data to the inverter, for example to carry out a limitation.

Hardware

Hoymiles DTU-WLite-S

How to disassemble the DTU?

00_disassembly

PCB / front

10_front_original 11_front_original

PCB / backside

20_rear_original 21_rear_original 22_rear_original

Modifications for logging

30_front_mod 31_front_mod 32_front_mod

Hoymiles DTU-Pro-S

PCB / front

10_front

PCB / backside

20_rear 21_rear_detail

Modifications for logging

30_mod_rear 31_mod_front 32_mod_converter

Sources