@ -102,6 +102,13 @@ const calcFunc_t<T> calcFunctions[] = {
|
|||
{ CALC_IRR_CH, &calcIrradiation }
|
||||
};
|
||||
|
||||
enum class InverterStatus : uint8_t {
|
||||
OFF,
|
||||
STARTING,
|
||||
PRODUCING,
|
||||
WAS_PRODUCING,
|
||||
WAS_ON
|
||||
};
|
||||
|
||||
template <class REC_TYP>
|
||||
class Inverter {
|
||||
|
@ -123,6 +130,9 @@ class Inverter {
|
|||
//String lastAlarmMsg;
|
||||
bool initialized; // needed to check if the inverter was correctly added (ESP32 specific - union types are never null)
|
||||
bool isConnected; // shows if inverter was successfully identified (fw version and hardware info)
|
||||
InverterStatus status; // indicates the current inverter status
|
||||
|
||||
static uint32_t *timestamp; // system timestamp
|
||||
|
||||
Inverter() {
|
||||
ivGen = IV_HM;
|
||||
|
@ -135,6 +145,7 @@ class Inverter {
|
|||
//lastAlarmMsg = "nothing";
|
||||
alarmMesIndex = 0;
|
||||
isConnected = false;
|
||||
status = InverterStatus::OFF;
|
||||
}
|
||||
|
||||
~Inverter() {
|
||||
|
@ -319,6 +330,9 @@ class Inverter {
|
|||
}
|
||||
else
|
||||
DPRINTLN(DBG_ERROR, F("addValue: assignment not found with cmd 0x"));
|
||||
|
||||
// update status state-machine
|
||||
isProducing();
|
||||
}
|
||||
|
||||
/*inline REC_TYP getPowerLimit(void) {
|
||||
|
@ -372,25 +386,39 @@ class Inverter {
|
|||
}
|
||||
}
|
||||
|
||||
bool isAvailable(uint32_t timestamp) {
|
||||
if((timestamp - recordMeas.ts) < INACT_THRES_SEC)
|
||||
return true;
|
||||
if((timestamp - recordInfo.ts) < INACT_THRES_SEC)
|
||||
return true;
|
||||
if((timestamp - recordConfig.ts) < INACT_THRES_SEC)
|
||||
return true;
|
||||
if((timestamp - recordAlarm.ts) < INACT_THRES_SEC)
|
||||
return true;
|
||||
return false;
|
||||
bool isAvailable() {
|
||||
bool val = false;
|
||||
if((*timestamp - recordMeas.ts) < INACT_THRES_SEC)
|
||||
val = true;
|
||||
if((*timestamp - recordInfo.ts) < INACT_THRES_SEC)
|
||||
val = true;
|
||||
if((*timestamp - recordConfig.ts) < INACT_THRES_SEC)
|
||||
val = true;
|
||||
if((*timestamp - recordAlarm.ts) < INACT_THRES_SEC)
|
||||
val = true;
|
||||
|
||||
if(val) {
|
||||
if((InverterStatus::OFF == status) || (InverterStatus::WAS_ON == status))
|
||||
status = InverterStatus::STARTING;
|
||||
} else
|
||||
status = InverterStatus::WAS_ON;
|
||||
|
||||
return val;
|
||||
}
|
||||
|
||||
bool isProducing(uint32_t timestamp) {
|
||||
bool isProducing() {
|
||||
bool val = false;
|
||||
DPRINTLN(DBG_VERBOSE, F("hmInverter.h:isProducing"));
|
||||
if(isAvailable(timestamp)) {
|
||||
if(isAvailable()) {
|
||||
uint8_t pos = getPosByChFld(CH0, FLD_PAC, &recordMeas);
|
||||
return (getValue(pos, &recordMeas) > INACT_PWR_THRESH);
|
||||
val = (getValue(pos, &recordMeas) > INACT_PWR_THRESH);
|
||||
|
||||
if(val)
|
||||
status = InverterStatus::PRODUCING;
|
||||
else if(InverterStatus::PRODUCING == status)
|
||||
status = InverterStatus::WAS_PRODUCING;
|
||||
}
|
||||
return false;
|
||||
return val;
|
||||
}
|
||||
|
||||
uint16_t getFwVersion() {
|
||||
|
@ -605,6 +633,9 @@ class Inverter {
|
|||
bool mDevControlRequest; // true if change needed
|
||||
};
|
||||
|
||||
template <class REC_TYP>
|
||||
uint32_t *Inverter<REC_TYP>::timestamp {0};
|
||||
|
||||
|
||||
/**
|
||||
* To calculate values which are not transmitted by the unit there is a generic
|
||||
|
|