mirror of
https://github.com/lumapu/ahoy.git
synced 2025-07-26 20:57:13 +02:00
added hardware info
This commit is contained in:
parent
3074b8ca4c
commit
a91885b505
7 changed files with 189 additions and 18 deletions
|
@ -10,7 +10,8 @@
|
|||
#include <cstdint>
|
||||
|
||||
// inverter generations
|
||||
enum {IV_HM = 0, IV_MI, IV_HMS, IV_HMT};
|
||||
enum {IV_MI = 0, IV_HM, IV_HMS, IV_HMT, IV_UNKNOWN};
|
||||
const char* const generationNames[] = {"HM", "MI", "HMS", "HMT", "UNKNOWN"};
|
||||
|
||||
// units
|
||||
enum {UNIT_V = 0, UNIT_A, UNIT_W, UNIT_WH, UNIT_KWH, UNIT_HZ, UNIT_C, UNIT_PCT, UNIT_VAR, UNIT_NONE};
|
||||
|
@ -21,20 +22,22 @@ enum {FLD_UDC = 0, FLD_IDC, FLD_PDC, FLD_YD, FLD_YW, FLD_YT,
|
|||
FLD_UAC, FLD_UAC_1N, FLD_UAC_2N, FLD_UAC_3N, FLD_UAC_12, FLD_UAC_23, FLD_UAC_31, FLD_IAC,
|
||||
FLD_IAC_1, FLD_IAC_2, FLD_IAC_3, FLD_PAC, FLD_F, FLD_T, FLD_PF, FLD_EFF,
|
||||
FLD_IRR, FLD_Q, FLD_EVT, FLD_FW_VERSION, FLD_FW_BUILD_YEAR,
|
||||
FLD_FW_BUILD_MONTH_DAY, FLD_FW_BUILD_HOUR_MINUTE, FLD_HW_ID,
|
||||
FLD_ACT_ACTIVE_PWR_LIMIT, /*FLD_ACT_REACTIVE_PWR_LIMIT, FLD_ACT_PF,*/ FLD_LAST_ALARM_CODE, FLD_MP};
|
||||
FLD_FW_BUILD_MONTH_DAY, FLD_FW_BUILD_HOUR_MINUTE, FLD_BOOTLOADER_VER,
|
||||
FLD_ACT_ACTIVE_PWR_LIMIT, FLD_PART_NUM, FLD_HW_VERSION, FLD_GRID_PROFILE_CODE,
|
||||
FLD_GRID_PROFILE_VERSION, /*FLD_ACT_REACTIVE_PWR_LIMIT, FLD_ACT_PF,*/ FLD_LAST_ALARM_CODE, FLD_MP};
|
||||
|
||||
const char* const fields[] = {"U_DC", "I_DC", "P_DC", "YieldDay", "YieldWeek", "YieldTotal",
|
||||
"U_AC", "U_AC_1N", "U_AC_2N", "U_AC_3N", "UAC_12", "UAC_23", "UAC_31", "I_AC",
|
||||
"IAC_1", "I_AC_2", "I_AC_3", "P_AC", "F_AC", "Temp", "PF_AC", "Efficiency", "Irradiation","Q_AC",
|
||||
"ALARM_MES_ID","FWVersion","FWBuildYear","FWBuildMonthDay","FWBuildHourMinute","HWPartId",
|
||||
"active_PowerLimit", /*"reactivePowerLimit","Powerfactor",*/ "LastAlarmCode", "MaxPower"};
|
||||
"ALARM_MES_ID","FWVersion","FWBuildYear","FWBuildMonthDay","FWBuildHourMinute","BootloaderVersion",
|
||||
"active_PowerLimit", "HWPartNumber", "HWVersion", "GridProfileCode",
|
||||
"GridProfileVersion", /*"reactivePowerLimit","Powerfactor",*/ "LastAlarmCode", "MaxPower"};
|
||||
const char* const notAvail = "n/a";
|
||||
|
||||
const uint8_t fieldUnits[] = {UNIT_V, UNIT_A, UNIT_W, UNIT_WH, UNIT_KWH, UNIT_KWH,
|
||||
UNIT_V, UNIT_V, UNIT_V, UNIT_V, UNIT_V, UNIT_V, UNIT_V, UNIT_A, UNIT_A, UNIT_A, UNIT_A,
|
||||
UNIT_W, UNIT_HZ, UNIT_C, UNIT_NONE, UNIT_PCT, UNIT_PCT, UNIT_VAR,
|
||||
UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_PCT, UNIT_NONE, UNIT_W};
|
||||
UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_PCT, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_NONE, UNIT_W};
|
||||
|
||||
// mqtt discovery device classes
|
||||
enum {DEVICE_CLS_NONE = 0, DEVICE_CLS_CURRENT, DEVICE_CLS_ENERGY, DEVICE_CLS_PWR, DEVICE_CLS_VOLTAGE, DEVICE_CLS_FREQ, DEVICE_CLS_TEMP};
|
||||
|
@ -98,11 +101,20 @@ const byteAssign_t InfoAssignment[] = {
|
|||
{ FLD_FW_BUILD_YEAR, UNIT_NONE, CH0, 2, 2, 1 },
|
||||
{ FLD_FW_BUILD_MONTH_DAY, UNIT_NONE, CH0, 4, 2, 1 },
|
||||
{ FLD_FW_BUILD_HOUR_MINUTE, UNIT_NONE, CH0, 6, 2, 1 },
|
||||
{ FLD_HW_ID, UNIT_NONE, CH0, 8, 2, 1 }
|
||||
{ FLD_BOOTLOADER_VER, UNIT_NONE, CH0, 8, 2, 1 }
|
||||
};
|
||||
#define HMINFO_LIST_LEN (sizeof(InfoAssignment) / sizeof(byteAssign_t))
|
||||
#define HMINFO_PAYLOAD_LEN 14
|
||||
|
||||
const byteAssign_t SimpleInfoAssignment[] = {
|
||||
{ FLD_PART_NUM, UNIT_NONE, CH0, 2, 4, 1 },
|
||||
{ FLD_HW_VERSION, UNIT_NONE, CH0, 6, 2, 1 },
|
||||
{ FLD_GRID_PROFILE_CODE, UNIT_NONE, CH0, 8, 2, 1 },
|
||||
{ FLD_GRID_PROFILE_VERSION, UNIT_NONE, CH0, 10, 2, 1 }
|
||||
};
|
||||
#define HMSIMPLE_INFO_LIST_LEN (sizeof(SimpleInfoAssignment) / sizeof(byteAssign_t))
|
||||
#define HMSIMPLE_INFO_PAYLOAD_LEN 14
|
||||
|
||||
const byteAssign_t SystemConfigParaAssignment[] = {
|
||||
{ FLD_ACT_ACTIVE_PWR_LIMIT, UNIT_PCT, CH0, 2, 2, 10 }/*,
|
||||
{ FLD_ACT_REACTIVE_PWR_LIMIT, UNIT_PCT, CH0, 4, 2, 10 },
|
||||
|
@ -242,4 +254,45 @@ const byteAssign_t hm4chAssignment[] = {
|
|||
#define HM4CH_PAYLOAD_LEN 62
|
||||
|
||||
|
||||
typedef struct {
|
||||
uint32_t hwPart;
|
||||
uint16_t maxPower;
|
||||
} devInfo_t;
|
||||
|
||||
const devInfo_t devInfo[] = {
|
||||
// MI 3rd gen
|
||||
{ 0x100230, 1500 },
|
||||
|
||||
// HM
|
||||
{ 0x101010, 300 },
|
||||
{ 0x101020, 350 },
|
||||
{ 0x101030, 400 },
|
||||
{ 0x101040, 400 },
|
||||
{ 0x101110, 600 },
|
||||
{ 0x101120, 700 },
|
||||
{ 0x101130, 800 },
|
||||
{ 0x101140, 800 },
|
||||
{ 0x101210, 1200 },
|
||||
{ 0x101230, 1500 },
|
||||
|
||||
// HMS
|
||||
{ 0x102021, 350 },
|
||||
{ 0x102041, 400 },
|
||||
{ 0x101051, 450 },
|
||||
{ 0x101071, 500 },
|
||||
{ 0x102111, 600 },
|
||||
{ 0x102141, 800 },
|
||||
{ 0x101151, 900 },
|
||||
{ 0x102171, 1000 },
|
||||
{ 0x102241, 1600 },
|
||||
{ 0x101251, 1800 },
|
||||
{ 0x102251, 1800 },
|
||||
{ 0x101271, 2000 },
|
||||
{ 0x102271, 2000 },
|
||||
|
||||
// HMT
|
||||
{ 0x103311, 1800 },
|
||||
{ 0x103331, 2250 }
|
||||
};
|
||||
|
||||
#endif /*__HM_DEFINES_H__*/
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue