mirror of
https://github.com/lumapu/ahoy.git
synced 2025-07-26 04:37:14 +02:00
0.8.39
* merge Prometheus metrics fix #1310 * merge MI grid profile request #1306
This commit is contained in:
parent
8e6f511549
commit
54b9e2f3ea
1 changed files with 9 additions and 10 deletions
|
@ -351,10 +351,9 @@ class Communication : public CommQueue<> {
|
|||
// small MI or MI 1500 data responses to 0x09, 0x11, 0x36, 0x37, 0x38 and 0x39
|
||||
//mPayload[iv->id].txId = p->packet[0];
|
||||
miDataDecode(p, q);
|
||||
} else if (p->packet[0] == (0x0f + ALL_FRAMES))
|
||||
} else if (p->packet[0] == (0x0f + ALL_FRAMES)) {
|
||||
miHwDecode(p, q);
|
||||
|
||||
else if (p->packet[0] == ( 0x10 + ALL_FRAMES)) {
|
||||
} else if (p->packet[0] == ( 0x10 + ALL_FRAMES)) {
|
||||
// MI response from get Grid Profile information request
|
||||
miGPFDecode(p, q);
|
||||
}
|
||||
|
@ -665,13 +664,13 @@ class Communication : public CommQueue<> {
|
|||
q->iv->setValue(2, rec, (uint32_t) (((p->packet[10] << 8) | p->packet[11]))); //FLD_GRID_PROFILE_CODE
|
||||
q->iv->setValue(3, rec, (uint32_t) (((p->packet[12] << 8) | p->packet[13]))); //FLD_GRID_PROFILE_VERSION
|
||||
|
||||
/* according to xlsx (different start byte -1!)
|
||||
Polling Grid-connected Protection Parameter File Command - Receipt
|
||||
byte[10] ST1 indicates the status of the grid-connected protection file. ST1=1 indicates the default grid-connected protection file, ST=2 indicates that the grid-connected protection file is configured and normal, ST=3 indicates that the grid-connected protection file cannot be recognized, ST=4 indicates that the grid-connected protection file is damaged
|
||||
byte[11] byte[12] CountryStd variable indicates the national standard code of the grid-connected protection file
|
||||
byte[13] byte[14] Version indicates the version of the grid-connected protection file
|
||||
byte[15] byte[16]
|
||||
*/
|
||||
/* according to xlsx (different start byte -1!)
|
||||
Polling Grid-connected Protection Parameter File Command - Receipt
|
||||
byte[10] ST1 indicates the status of the grid-connected protection file. ST1=1 indicates the default grid-connected protection file, ST=2 indicates that the grid-connected protection file is configured and normal, ST=3 indicates that the grid-connected protection file cannot be recognized, ST=4 indicates that the grid-connected protection file is damaged
|
||||
byte[11] byte[12] CountryStd variable indicates the national standard code of the grid-connected protection file
|
||||
byte[13] byte[14] Version indicates the version of the grid-connected protection file
|
||||
byte[15] byte[16]
|
||||
*/
|
||||
/*if(mSerialDebug) {
|
||||
DPRINT(DBG_INFO,F("ST1 "));
|
||||
DBGPRINTLN(String(p->packet[9]));
|
||||
|
|
Loading…